AutoCAD 2D
Mechanical Power graduate, Faculty of Engineering, Cairo University year 2010 Graduation project (Air conditioning systems Design and control) Accredited Tier Designer (Uptime Institute) Turnkey Datacenter Design Solution Extensive knowledge of MEP systems & components. Work Experience in GCC Quick study, with an ability to easily grasp and put into application new ideas, concepts, methods and technologies, dedicated, innovative and self-motivated team player / builder. Ability to work under pressure and handle multiple tasks and good negotiation skills. Proficient in the use of various computer programs and applications. (Autocad 2D - Microsoft Office Excel, Visio &Word) Fluent English
Sales strategies
Networking and relationship building
Datacenter Infra structure Design
Business development and planning
AutoCAD 2D
Hourly Analysis Program
Microsoft Office
CFD
Accredited Tier Designer - UPTIME Institute
**Notable Projects:**
1- Administrative control authority new Datacenter in New capital City (Completed)
- TIER III datacenter turnkey solution design and selection
- 112 Racks w/PDUs (2x1000 KVA UPS System)
- 4 Cold Aisle Containment
- 18 Dual Circuit Computer Room Air Handling Units
- DCIM software and Environmental Sensors
- MEP System
2- Standard Chartered Bank Datacenter – First Branch in Egypt (Completed)
- Smart Aisle Containment V2.0
- 16 Racks w/PDUs (2x30 KVA UPS system)
- In-Row Cooling Units
- DCIM Software and Environmental Sensors
3- First Abu Dhabi Bank Datacenter – New HQ (Completed)
- TIER III datacenter turnkey solution design and selection
- 92 Racks w/PDUs (2x600 KVA UPS System)
- 6 Cold Aisle Containment
- 15 Dual Fluid Computer Room Air Conditioning Units
- DCIM software and Environmental Sensors
4- Shefa Al Orman Hospital Datacenter (In Progress)
- TIER III datacenter turnkey solution design and selection
- 18 Racks w/PDUs (2x80 KVA UPS system)
- 1 Cold Aisle Containment
- 3 Dual Fluid Computer Room Air Conditioning Units
- DCIM software and Environmental Sensors
- CCTV, Access Control & Water leakage system
5- Four Seasons Sharm Al Sheikh Hotel Datacenter (Completed)
- TIER III datacenter turnkey solution design and selection
- 16 Racks w/PDUs (2x60 KVA UPS system)
- 1 Cold Aisle Containment
- 3 DX Computer Room Air Conditioning Units
- DCIM software and Environmental Sensors
- CCTV, Access Control & Water leakage system
6- Cairo Festival City (Al Sewedy Electric) Datacenter (Completed)
- 12 Racks w/PDUs (2x60 KVA UPS system)
- 2 Cold Aisle Containment
- 3 DX Computer Room Air Conditioning Units
- DCIM software and Environmental Sensors
Accredited Tier Designer - UPTIME Institute